INSTRUMENTS

Code : SE300

SE300 Lab Grade Double Junction ORP Platinum Probe

SE300 Lab Grade Double Junction ORP Platinum Probe SE300 probe is designed for use with the Milwaukee MW500 PRO ORP Meter.   SPECIFICATIONS Body: Resin Reference: Single, Ag/AgCl Junction: Ceramic, single Electrolyte: Gel Max pressure: 2 Bar Range: ORP: ±2000 mV Tip Shape: Platinum pin Diameter: 0.5 inches Dimensions: 4.7 inches / 6.4 inches Operating Temperature: -5 to 70°C (23 to 158°F) Cable length: 3.3 feet Connection: BNC
  • Download
Code : SE510

SE510 Lab Grade EC/TDS Probe

SE510 Lab Grade EC/TDS Probe SE510 Conductivity (EC)/ Total Dissolved Solids (TDS) probe is designed for use with the Milwaukee MW301 and MW401 PRO Conductivity Meters. This probe features a DIN connector and 3' (1 m) cable.  
  • Download
Code : SE520

SE520 Lab Grade EC/TDS Probe

SE520 Lab Grade EC/TDS Probe SE520 Conductivity (EC)/ Total Dissolved Solids (TDS) probe is designed for use with the Milwaukee MW302 and MW402 PRO Conductivity/TDS Meters. This probe features a DIN connector and 3' (1 m) cable.
  • Download
Code : SE600

SE600 Lab Grade Combo pH / EC / TDS Probe

SE600 Lab Grade Combo pH / EC / TDS Probe SE600 probe is designed for use with the Milwaukee MW801 and MW802 PRO 3-in-1 pH, EC, TDS Combo Meters.   SPECIFICATIONS Body: Polypropylene Reference: Single, Ag/AgCl Junction: Cloth Electrolyte: Gel pH Range: 0 - 13 pH Temp Range: 20 - 40 C (68 - 104 F) Tip Shape: Spheric Max. Pressure: 0.1 bar Length: 3.8 inches Cable length: 7 pole / 3.3 feet Connection: DIN
  • Download
Code : MA814DB/1

MA814DB/1 EC/TDS/Temp Replacement Probe

MA814DB/1 EC/TDS/Temp Replacement Probe The Milwaukee 4 Ring MA814DB/1 is the replacement EC/TDS/Temp Probe for MW170 & MW180 Bench EC/TDS/Temp meters.  The MA814DB/1 has a rugged body designed to take hits and comes with a 1 meter (3') cable and a DIN connector (meter(s) sold separately). The probe connects quickly and tightly with a screw on DIN. No worries of slipping off.
Code : MA815D/1

MA815D/1 Lab Grade EC/TDS/NaCl/Temp Replacement Probe

MA815D/1 Lab Grade EC/TDS/NaCl/Temp Replacement Probe MA815D/1 Conductivity (EC)/ Total Dissolved Solids (TDS) / NaCl / Temperature probe is designed for use with the Milwaukee MW306 MAX Conductivity/TDS/NaCl/Temp Meter. This probe features a DIN connector and 3' (1 m) cable.
  • Download
Code : MA911B/2

MA911B/2 Lab Grade Double Junction pH Electrode with Extended Cable

MA911B/2 Lab Grade Double Junction pH Electrode with Extended Cable MA911B/2 probe is lab grade, gel-filled pH probe for use with Milwaukee Monitors and Controllers.   SPECIFICATIONS Body: Resin Reference: Single, Ag/AgCl Junction: Ceramic, Double Electrolyte: Gel Range: 0-14 pH Tip Shape: Sphere Diameter: 0.5 inches Dimensions: 4.7 inches / 6.4 inches Operating Temperature: -5 to 70°C (23 to 158°F) Cable length: 6.6 feet Connection: BNC
  • Download
Code : MA906BR/1

MA906BR/1 Amplified pH/mV/Temp Replacement electrode

MA906BR/1 Amplified pH/mV/Temp Replacement electrode MA906BR/1 Amplified pH/mV/Temp replacement probe for Milwaukee MW105 pH/Temp and MW106 pH/mV/temp meters. The MA906BR/1 has a rugged body (Epoxy) designed to take hits, comes with a 1 meter (3') cable and a BNC connector (meter(s) sold separately).  The MA906BR/1 will read mV of pH.  OPR probes for MW105 or MW106 sold separately (MA921B/2).  The probe connects quickly and tightly with a BNC connector. No worries of slipping off.   SPECIFICATIONS Body: Resin Reference: Single, KCL Junction: Ceramic, Double Electrolyte: Gel Range: 0-12 pH Temperature Range: -5 to 70°C (23 to 123°F) Accuracy: +/- 0.02 pH Tip Shape: Sphere Diameter: 0.5 inches Length: 6.4 inches Cable length: 3.2 feet (1 m) Connection: BNC
  • Download
Code : MA921B/2

MA921B/2 Lab Grade Double Junction ORP Platinum Probe with Extended Cable

MA921B/2 Lab Grade Double Junction ORP Platinum Probe with Extended Cable SPECIFICATIONS Body: PEI Resin Reference: Double, Ag/AgCl Junction: Ceramic Electrolyte: Gel ORP Range: ±2000 mV Tip Shape: platinum pin Dimensions: 6.4 inches Recommended Operating Temperature: -5 to 70°C (23 to 158°F) Cable length: 6.6 feet Connection: BNC
  • Download
Code : MA831R

MA831R Stainless Steel Temperature Replacement Probe

MA831R Stainless Steel Temperature Replacement Probe MA831R is the replacement Temperature Probe for MAX Bench meters MW150, MW151, MW160, MW180, PRO Portable meter MW102 and the MI456 Mini Titrator. The MA831R has a rugged, easy-to-clean stainless steel body designed to take hits and comes with a 1 meter cable (meter(s) sold separately).  
  • Download
Code : MA840

MA840 Polarographic Dissolved Oxygen Probe

MA840 Polarographic Dissolved Oxygen Probe MA840 is a polarographic replacement probe for the MW600 Dissolved Oxygen meter. The refillable polarographic probe has an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor for measuring dissolved oxygen (DO) levels in aqueous solutions. The probe uses a platinum cathode and a silver chloride anode which the MW600 meter polarizes so that oxygen passing through the membrane can be measured to produce stable, accurate readings.  
  • Download
Code : MA845

MA845 Polarographic Dissolved Oxygen Probe

MA845 Polarographic Dissolved Oxygen Probe MA845 is a polarographic replacement probe for the MW190 MAX Dissolved Oxygen Bench Meter. The refillable polarographic probe has an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor for measuring dissolved oxygen (DO) levels in aqueous solutions. The probe uses a platinum cathode and a silver chloride anode which the MW190 MAX meter polarizes so that oxygen passing through the membrane can be measured to produce stable, accurate readings.  
  • Download
Code : MA860

MA860 Galvanic Dissolved Oxygen Probe

MA860 Galvanic Dissolved Oxygen Probe MA860 is a Galvanic replacement probe for the MW605 MAX Dissolved Oxygen meter. The refillable Galvanic probe has an oxygen-permeable polytetrafluroethylene (PTFE) membrane sensor for measuring dissolved oxygen (DO) levels in aqueous solutions and a built  in temperature sensor. The probe uses a silver cathode and a zinc anode.  Its body is made of PP, ABS.   SPECIFICATIONS Probe MA860: Galvanic Probe Temperature Range: 0.0 to 50.0°C / 32.0 to 122.0°F Temperature Sensor: Built-in Thermistor Cathode: Silver Anode: Zinc Membranes: Oxygen permeable PTFE (MA861) Connector Socket: DIN 7pins Body: PP, ABS, IP67 rating Cable: Jacket material: PP
  • Download

Send Enquiry