MW170 MAX EC/TDS/NaCl/Temp Logging Bench Meter
The Milwaukee MW170 4-in-1 MAX EC/TDS/NaCl/Temp. Logging Bench Meter has won fans around the world with its reliable, fast and simple operation as well as its tough, sleek design and small benchtop footprint. It is accurate to ± 1% of reading for EC/TDS & Salinity with automatic, manual or no temperature compensation and a built in dedicated GLP key. Ideal for use by education, horticulture, labs, food processing, water treatment and many other applications with challenging EC/TDS/NaCL/Temp. measurement needs.
SPECIFICATIONS
- EC Range: 0.00 to 29.99 uS/cm / 30.0 to 299.9 uS/cm
- EC Range: 300 to 2999 uS/cm
- EC Range: 3.00 to 29.99 mS/cm / 30.0 to 200.0 mS/cm
- EC Range: up to 500 mS/cm absolute conductivity**
- TDS Range: 0.00 to 14.99 ppm (mg/L)
- TDS Range: 15.0 to 149.9 ppm (mg/L) / 150 to 1499 ppm (mg/L)
- TDS Range: 1.50 to 14.99 g/L / 15.0 to 100.0 g/l
- TDS Range: upt to 250.0 g/L absolute TDS**
- TDS Range: up to 400 g/L absolute TDS** (with 0.80 factor)
- Salinity Range: 0.0 to 400.0% NaCl / 2.00 to 42.00 PSU
- Salinity Range: 0.00 to 80.00 g/L
- Temp. Range: -20.0 to 120.00°C (-4.0 to 248.0°F)
- EC Resolution: 0.01 uS/cm / 0.1 uS/cm / 1 uS/cm
- EC Resolution: 0.01 mS/cm / 0.1 mS/cm
- TDS Resolution: 0.01 ppm / 0.1 ppm / 1 ppm
- TDS Resolution: 0.01 g/L / 0.1 g/L
- Salinity Resolution: 0.1% NaCl / 0.01 PSU / 0.01 g/L
- Temperature Resolution: 0.1°C / 0.1°F)
- Accuracy @ 25°C / 77°F
- EC: ± 1% of reading / ±0.05 uS/cm or 1 digit, whichever is greater
- TDS: ±1% of reading / ±0.03 ppm or 1 digit, whichever is greater
- Salinity: ±1% of reading
- Temperature: ±0.5°C (±0.9°F)
- Calibration
- EC/TDS: single cell factor calibration, 6 standards: 84 uS/cm, 1413 uS/cm, 5.00 mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm / one point offset: 0.00 uS/cm
- Salinity: one point with MA9066 salinity calibration solution
- Temperature Compensation: Automatic or manual from -20 to 120°C (-4.0 to 248.0°F) or NO TC without temperature compensation
- Conductivity temperature coefficient: 0.00 to 6.00 % / °C (EC and TDS only) | Default value: 1.90 % / °C
- TDS factor: 0.40 to 0.80 / Default value: 0.50
- EC Probe: MA814DB/1 4 ring
- Temperature probe: Built-in temperature sensor
- Logging: Maximum 1,000 log records (stored in up to 100 lots) / on demand, 200 logs on stability, 200 logs, interval logging 1000
- PC Connectivity: 1 micro USB port
- Power Supply: 12 VDC adapter (included)
- Battery Type: Internal
- Battery life: Approx. 8 hours of use
- Environment: 0 to 50°C / 32 to 122°F; max RH 95%
- Dimensions: 230 x 160 x 95 mm (9.0 x 6.3 x 3.7 inches)
- Weight: 0.9 kg / 2.00 lbs.