INSTRUMENTS

Code : MW10

Free Chlorine Photometer Handy

  Discription: Range 0.00 to 2.50 ppm Resolution 0.01 ppm Accuracy ±0.03 ppm ±3% of reading @ 25 °C Typical EMC Dev. ±0.01 ppm Light Source Light Emitting Diode @ 525 nm Light Detector Silicon Photocell Method Adaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample. Environment 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing Battery Type 1 x 1.5V AAA Auto-shut off After 2 minutes of non-use. Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.)   ACCESSORIES Mi526-25 Free Chlorine powder reagent, 25 pcs. (old 2720116) Mi0011 10 mL small glass cuvets (2 pcs) Mi0013 Stoppers for Mi0011 glass cuvets (2 pcs)   ORDERING INFORMATION All brand new handy photometers are supplied in carton box including 2 cuvets, reagents and instruction manual.          
Code : MW11

Total Chlorine Photometer Handy

  Range 0.00 to 3.50 ppm Resolution 0.01 ppm Accuracy ±0.03 ppm ±3% of reading @ 25 °C Typical EMC Dev. ±0.01 ppm Light Source Light Emitting Diode @ 525 nm Light Detector Silicon Photocell Method Adaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample. Environment 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing Battery Type 1 x 1.5V AAA Auto-shut off After 2 minutes of non-use. Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.) ACCESSORIES Mi524-25 Total Chlorine powder reagent, 25 pcs. (old 2720216) Mi0011 10 mL small glass cuvets (2 pcs) Mi0013 Stoppers for Mi0011 glass cuvets (2 pcs)   ORDERING INFORMATION All brand new handy photometers are supplied in carton box including 2 cuvets, reagents and instruction manual.          
  • Download
Code : MW12

Phosphate Photometer Handy

  SPECIFICATIONS Range 0.00 to 2.50 ppm Resolution 0.01 ppm Accuracy ±0.04 ppm ±4% of reading @ 25 °C Typical EMC Dev. ±0.01 ppm Light Source Light Emitting Diode @ 525 nm Light Detector Silicon Photocell Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20th edition, Ascorbic Acid method. The reaction between phosphate and the reagent causes a blue tint in the sample. Environment 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing Battery Type 1 x 1.5V AAA Auto-shut off After 3 minutes of non-use and 2 minutes after reading. Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.)   ACCESSORIES Mi512-25 Phosphate powder reagent, 25 pcs. (old 2720115) Mi0011 10 mL small glass cuvets (2 pcs) Mi0013 Stoppers for Mi0011 glass cuvets (2 pcs)   ORDERING INFORMATION All brand new handy photometers are supplied in carton box including 2 cuvets, reagents and instruction manual.          
  • Download
Code : MW13

Inodine Photometer Handy

SPECIFICATIONS Range 0.0 to 12.5 ppm Resolution 0.1 ppm Accuracy ±0.1 ppm ±5% of reading @ 25 °C Light Source Light Emitting Diode @ 525 nm Light Detector Silicon Photocell Method Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th edition, DPD method. The reaction between iodine and the reagent causes a pink tint in the sample. Environment 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing Temperature Compensation Automatic between 10 and 40°C / 50 to 104°F Battery Type 1 x 1.5V AAA Auto-shut off After 2 minutes of non-use. Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.)   ACCESSORIES Mi527-25 Iodine powder reagent, 25 pcs. (old 2720316) Mi0011 10 mL small glass cuvets (2 pcs) Mi0013 Stoppers for Mi0011 glass cuvets (2 pcs)   ORDERING INFORMATION All brand new handy photometers are supplied in carton box including 2 cuvets, reagents and instruction manual.    
Code : MW14

Iron Photometer Handy

SPECIFICATIONS Range 0.00 to 5.00 ppm Resolution 0.01 ppm Accuracy ±0.04 ppm ±2% of reading @ 25 °C Typical EMC Dev. ±0.01 ppm Light Source Light Emitting Diode @ 525 nm Light Detector Silicon Photocell Method Adaptation of the EPA Phenantroline method 315B, for natural and treated waters. The reaction between iron and reagent causes an orange tint in the sample. Environment 0 to 50°C (32 to 122 °F) max. 95% RH non-condensing Battery Type 1 x 1.5V AAA Auto-shut off After 3 minutes of non-use and 2 minutes after reading. Dimensions 81.5 x 61 x 37.5 mm (3.2 x 2.4 x 1.5”) Weight 64 g (2.25 oz.) ACCESSORIES Mi528-25 Iron powder reagent, 25 pcs. (old 2720416) Mi0011 10 mL small glass cuvets (2 pcs) Mi0013 Stoppers for Mi0011 glass cuvets (2 pcs)   ORDERING INFORMATION All brand new handy photometers are supplied in carton box including 2 cuvets, reagents and instruction manual.          
Code : MI404

Free & Total Chlorine Professional Photometer

Milwaukee provides a range of chlorine photometers for all applications: swimming pool treatments, household cleaners, dishwasher additives, laundry powders/liquids and cooling water treatment products all contain chlorine as an oxidizing biocide. Drinking water contains residual chlorine to maintain water purity throughout the supply lines. Milwaukee offers the Mi404, a microprocessor-based instrument with greater resolution, better accuracy and immediate results for measuring free (0.00 to 5.00 mg/L) and total (0.00 to 5.00 mg/L) chlorine. SPECIFICATIONS Free Chlorine Range 0.00 to 5.00 mg/L Cl2 Total Chlorine Range 0.00 to 5.00 mg/l Cl2 Free Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) Total Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) Free Chlorine Accuracy ±0.04 mg/l @1.50 mg/l Total Chlorine Accuracy ±0.04 mg/l @1.50 mg/l Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G Light Source tungsten lamp Light Detector silicon photocell and 525 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g   ACCESSORIES Mi504-100 Free & Total Chlorine reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi404 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.          
Code : MI405

Ammonia (Medium Range) Professional Photometer

This user-friendly Colorimeter will give you direct readings in mg/L.
Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators. Ammonia is highly soluble in water and extremely toxic to fish. Fish farm owners must monitor and maintain careful control of ammonia levels to ensure optimum water conditions for their stock. Milwaukee offers the Mi405 Photometer with a range of 0.00 to 9.99 mg/L, for medium concentrations.   SPECIFICATIONS Range 0.00 to 9.99 mg/l (NH3-N) Resolution 0.01 mg/l Accuracy ±0.10 mg/l @5.00 mg/l Method adaptation of Nessler method Sorgente luminosa Blue LED 466 nm Light Detector silicon photocell and 466 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g ACCESSORIES Mi505-100 Ammonia MR reagent (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi405 is supplied complete with 2 cuvets, reagents for 100 tests, hard carrying case, wiping tissue, 9V battery and in          
Code : MI406

Free Chlorine Professional Photometer

Milwaukee provides a range of chlorine photometers for all applications: swimming pool treatments, household cleaners, dishwasher additives, laundry powders/liquids and cooling water treatment products all contain chlorine as an oxidizing biocide. Drinking water contains residual chlorine to maintain water purity throughout the supply lines. Milwaukee offer the Mi406 microprocessor-based instrument with greater resolution, better accuracy and immediate results, for measuring free chlorine (0.00 to 5.00 mg/L). SPECIFICATIONS Free Chlorine Range 0.00 to 5.00 mg/l Cl2 Free Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) Free Chlorine Accuracy ±0.04 mg/l @1.50 mg/l Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G Light Source tungsten lamp Light Detector silicon photocell and 525 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g   ACCESSORIES Mi506-100 Free Chlorine reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi406 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.          
Code : MI407

Ammonia (Low Range) Professional Photometer

This user-friendly Colorimeter will give you direct readings in mg/L. Ammonia detection in water treatment systems is particularly important for aquarium owners and fish farm operators. Ammonia is highly soluble in water and extremely toxic to fish. Fish farm owners must monitor and maintain careful control of ammonia levels to ensure optimum water conditions for their stock. Milwaukee offers the Mi407 microprocessor-based instrument with greater resolution, better accuracy and immediate results for measuring low concentrations of Ammonia (from 0.00 to 3.00 mg/L). SPECIFICATIONS Ammonia Range 0.00 to 3.00 mg/l (NH3-N) Ammonia Resolution 0.01 mg/l Ammonia Accuracy ±0.04 mg/l @1.50 mg/l Method adaptation of Nessler method Light Source Blu LED 466 nm Light Detector silicon photocell and 466 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g ACCESSORIES Mi507-100 Ammonia Low Range reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi407 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.          
Code : MI408

Iron (High Range) Professional Photometer

This user-friendly Colorimeter will give you direct readings in mg/L. Iron is naturally present in water supplies and its presence in both potable and industrial applications is regarded as objectionable. Milwaukee offers Mi408 microprocessor-based instrument with greater resolution, better accuracy and immediate results for measuring high concentrations of Iron (from 0.00 to 5.00 mg/L). SPECIFICATIONS Iron Range 0.00 to 5.00 mg/l Fe Iron Resolution 0.01 mg/l Iron Acuuracy ±0.03 mg/l @1.50 mg/l Method adaptation of the USEPA method 315 and Standard method 3500 - Fe B Light Source tungsten lamp Light Detector silicon photocell and 525 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g ACCESSORIES Mi508-100 Iron High Range reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi408 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.          
Code : MI411

Free & Total Chlorine and pH Professional Photometer

3 in 1 Combination Photometer.
This latest laboratory grade Microprocessor photometer has an excellent repeatability and is ideal for field measurements. Chlorine is the most commonly used water disinfectant.
Applications vary from treatment of drinking water and wastewater to pool and spa sanitization and food processing to sterilization. Milwaukee Instruments has developed the Mi411, a portable microprocessor based instrument to measure three critical parameters to ensure good water quality: pH, free chlorine and total chlorine.
This instrument provides greater resolution, better accuracy and immediate results. Mi411 is supplied in a hard carrying case including 2 cuvets, reagents for 100 tests, wiping tissue and instruction manua Hard Carrying Case
Mi411 comes complete in hard carrying case, making it ideal for field measurements. SPECIFICATIONS Free Chlorine Range 0.00 to 5.00 mg/l Cl2 Total Chlorine Range 0.00 to 5.00 mg/l Cl2 pH Range 6.5 to 8.0 pH Free Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) Total Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) pH Resolution 0.1 pH Free Chlorine Accuracy ±0.04 mg/l @1.50 mg/l Total Chlorine Accuracy ±0.04 mg/l @1.50 mg/l pH Accuracy pH ±0.1 pH @7.2 pH Free Chlorine Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G Free Chlorine Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G pH Method adaptation of the phenol red method Light Source tungsten lamp Light Detector silicon photocell and 525 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g     Glass Cuvets
Mi411 is supplied complete with 2 cuvets, liquid reagents for 100 tests, hard carrying case, wiping tissue, 9V battery and instructions.     ACCESSORIES Mi504-100 Free & Total Chlorine reagent set (100 tests) Mi509-100 pH reagent (100 tests) Mi511-100 Free & Total Chlorine and pH reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi411 is supplied complete with 2 cuvets, liquid reagents for 100 tests, hard carrying case, wiping tissue, 9V battery and instructions.            
Code : MI412

Phosphate (Low Range) Professional Photometer

This user-friendly Colorimeters will give you direct readings in mg/L. Phosphates are present in natural waters and at concentrations typically found, do not pose any specific health threats to humans. However, excessive contamination of water courses from agricultural fertilizer run off or wastewater/effluent discharge can promote excessive algae or plant growth. Milwaukee offers Mi412 with range 0.00 to 2.50 mg/L. SPECIFICATIONS Phosphate Range  0.00 to 2.50 mg/l PO4 Resolution Range 0.01 mg/l Accuracy Range ±0.04 mg/l @1.00 mg/l Method adaptation of Ascorbic Acid method Light Source tungsten lamp Light Detector silicon photocell and 610 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g   ACCESSORIES Mi512-100 Phosphate Low Range reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi412 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.        
Code : MI413

Free & Total Chlorine (High Range) Professional Photometer

Milwaukee provides a range of chlorine photometers for all applications: swimming pool treatments, household cleaners, dishwasher additives, laundry powders/liquids and cooling water treatment products all contain chlorine as an oxidizing biocide. Drinking water contains residual chlorine to maintain water purity throughout the supply lines. Milwaukee offer the Mi413 microprocessor-based instrument with greater resolution, better accuracy and immediate results, for measuring free (0.00 to 10.00 mg/L) and total (0.00 to 10.00 mg/L) chlorine. SPECIFICATIONS Free Chlorine Range 0.00 to 10.00 mg/l Cl2 Total Chlorine Range 0.00 to 10.00 mg/l Cl2 Free Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) Total Chlorine Resolution 0.01 mg/l (0.00 to 3.50 mg/l); 0.10 mg/l (above 3.50 mg/l) Free Chlorine Accuracy ±0.10 mg/l @5.00 mg/l Total Chlorine Accuracy ±0.10 mg/l @5.00 mg/l Method adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G Light Source tungsten lamp Light Detector silicon photocell and 525 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g   ACCESSORIES Mi513-045 Free & Total Chlorine reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi413 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.          
Code : MI414

Chloride Professional Photometer

Chlorides are used by the water treatment professional to determine cycles of concentration in low pressure boilers and cooling systems. It is essential to monitor chloride concentrations in boiler systems to prevent metal parts being damaged. In high levels, chloride can corrode stainless steel. Milwaukee offers MI414 microprocessor-based instrument with greater resolution, better accuracy and immediate results for measuring chloride (0.00 to 20.00 mg/L). SPECIFICATIONS Chloride Range 0.00 to 20.00 mg/l Cl¯ Chloride Resolution 0.01 mg/l Chloride Accuracy ±0.4 mg/l @10.0 mg/l Method Adaptation of mercury (II) thiocyanate method Light Source Blu LED 466 nm Light Detector silicon photocell and 466 nm narrow band interference filter Environment 0 to 50°C / 32 to 122°F; max RH 100% Battery Type 1 x 9V (included) Auto-off after 10 minutes of non-use Dimensions 192 x 104 x 52 mm Weight 380 g   ACCESSORIES Mi514-100 Chloride reagent set (100 tests) Mi0001 Glass cuvets (2 pcs) Mi0002 Caps for cuvets (2 pcs) Mi0003 Stoppers for cuvets (2 pcs)   ORDERING INFORMATION Mi414 is supplied complete with 2 cuvets, reagents, hard carrying case, wiping tissue, 9V battery and instructions.        

Send Enquiry